7 43 0 0 00 0 0 0 0 0 0 0 0 (0)AMPE0 0 (0)AMPE1 0 (0)AMPE2 0 (0)AMPE3 0Reserved 0 (0)IREFE

AMPE1=0, IREFE=0, AMPE0=0, AMPE2=0, AMPE3=0

Description

Operational amplifier control register

Fields

AMPE0

Operation control of operational amplifier(UNIT0)

0 (0): Operation amplifier is stopped.

1 (1): Software trigger mode: Operation of operational amplifier is enabled Operation of the operational amplifier reference current circuit is also enabled regardless of the IREFE bit se An activation trigger mode or An activation and A/D trigger mode: Wait for AGT is enabled.

AMPE1

Operation control of operational amplifier(UNIT1)

0 (0): Operation amplifier is stopped.

1 (1): Software trigger mode: Operation of operational amplifier is enabled Operation of the operational amplifier reference current circuit is also enabled regardless of the IREFE bit se An activation trigger mode or An activation and A/D trigger mode: Wait for An activation is enabled.

AMPE2

Operation control of operational amplifier(UNIT2)

0 (0): Operation amplifier is stopped.

1 (1): Software trigger mode: Operation of operational amplifier is enabled Operation of the operational amplifier reference current circuit is also enabled regardless of the IREFE bit se An activation trigger mode or An activation and A/D trigger mode: Wait for An activation is enabled.

AMPE3

Operation control of operational amplifier(UNIT3)

0 (0): Operation amplifier is stopped.

1 (1): Software trigger mode: Operation of operational amplifier is enabled Operation of the operational amplifier reference current circuit is also enabled regardless of the IREFE bit se An activation trigger mode or An activation and A/D trigger mode: Wait for An activation is enabled.

Reserved

These bits are read as 000. The write value should be 000.

IREFE

Operation control of operational amplifier reference current circuit

0 (0): Operational amplifier reference current circuit is stopped.

1 (1): Operation of operational amplifier reference current circuit is enabled.